Model
|
SUN-5K-SG01HP3-EU-AM2
|
SUN-6K-SG01HP3-EU-AM2
|
SUN-8K-SG01HP3-EU-AM2
|
SUN-10K-SG01HP3-EU-AM2
|
SUN-12K-SG01HP3-EU-AM2
|
SUN-15K-SG01HP3-EU-AM2
|
SUN-20K-SG01HP3-EU-AM2
|
Battery Input Data
|
|
Battery Type
|
Lithium-ion
|
Battery Voltage Range(V)
|
160-700
|
Max. Charging Current(A)
|
37
|
Max .Discharging Current(A)
|
37
|
Number of battery input
|
1
|
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
PV String Input Data
|
|
Max. DC Input Power(W)
|
6500
|
7800
|
10400
|
13000
|
15600
|
19500
|
26000
|
Max. DC Input Voltage(V)
|
1000
|
Start-up Voltage(V)
|
180
|
MPPT Range(V)
|
150-850
|
Full LoadDC Voltage Range (V)
|
195-850
|
195-850
|
260-500
|
325-500
|
340-500
|
420-500
|
500-500
|
Rated DC Input Voltage(V)
|
600
|
PV Input Current(A)
|
20+20
|
26+20
|
26+26
|
Max. PVIsc(A)
|
30+30
|
39+30
|
39+39
|
No. of MPP Trackers
|
2
|
No.of Strings per MPP Tracker
|
1
|
2+1
|
2
|
AC Output Data
|
|
Rated AC Output Active Power(W)
|
5000
|
6000
|
8000
|
10000
|
12000
|
15000
|
20000
|
Max AC Output Active Power(W)
|
5500
|
6000
|
8800
|
11000
|
13200
|
16500
|
22000
|
AC Output Rated Current(A)
|
7.6/7.3
|
9.1/8.7
|
12.2/11.6
|
15.2/14.5
|
18.2/17.4
|
22.8/21.8
|
30.4/29
|
Max. AC Output Rated Current(A)
|
8.4/8
|
10/9.6
|
13.4/12.8
|
16.7/16
|
20/19.2
|
25/24
|
33.4/31.9
|
Max.Three-phase Unbalanced Output Current(A)
|
13
|
13
|
18
|
22
|
25
|
30
|
35
|
Max. ContinuousAC Passthrough(A)
|
40
|
80
|
Peak Power(off grid)
|
1.5 time of rated power, 10 S
|
Generator input/Smartload/AC couple current(A)
|
7.6/40/7.6
|
9.1/40/9.1
|
12.2/40/12.2
|
15.2/40/15.2
|
18.2/80/18.2
|
22.8/80/22.8
|
30.4/80/30.4
|
Power Factor Adjustment Range
|
0.8 leading to 0.8 lagging
|
Output Frequency and Voltage
|
50/60Hz; 3L/N/PE 220/380, 230/400Vac
|
Grid Type
|
Three Phase
|
Total Harmonic Distortion(THD)
|
<3% (of nominal power)
|
DC current injection
|
<0.5% In
|
Efficiency
|
|
Max.Efficiency
|
97.60%
|
EuroEfficiency
|
97.00%
|
MPPTEfficiency
|
99.90%
|
Protection
|
|
Integrated
|
PV Input Lightning Protection,Anti-islandingProtection, PV String Input Reverse PolarityProtection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, OutputShorted Protection, Surge protection
|
Output Over Voltage Protection
|
DCType II/AC Type III
|
Certifications and Standards
|
|
Grid Regulation
|
VDE4105,IEC61727/62116,VDE0126,AS4777.2,CEI0 21,EN50549-1,G98,G99,C10-11,UNE217002,NBR16149/NBR16150
|
Safety EMC/Standard
|
IEC/EN 61000-6-1/2/3/4, IEC/EN62109-1, IEC/EN 62109-2
|
General Data
|
|
Operating Temperature Range(℃)
|
-40-60℃,>45℃ derating
|
Cooling
|
Smart cooling
|
Noise(dB)
|
≤55 dB
|
Communication with BMS
|
RS485; CAN
|
Weight(kg)
|
30.5
|
Size (mm)
|
408W×638H×237D
|
Protection Degree
|
IP65/td>
|
Installation Style
|
Wall-mounted
|
Warranty
|
5 years
|